AT-profile PU timing belt with Kevlar (aramid) tensile cord. Non-metallic reinforcement for use in MRI rooms, clean rooms, and other magnetic- or particle-sensitive environments.
AT5 / AT10 aramid-cord PU belts avoid the eddy-current distortion that steel-cord belts cause inside MRI bores — they are the go-to for patient-positioning drives inside the scanner room.